Ra tells you the average roughness of a surface. Rz tells you how deep its worst valleys go. On medical parts you usually need both, because a surface can hit its Ra target while still hiding a single deep groove that traps residue or leaks past a seal. If your drawing only says "Ra 0.4", you have left the acceptance criteria open to interpretation — and interpretation is where inspection arguments start.
Key takeaways
• Ra and Rz describe different things. Ra is an arithmetic average; Rz is a peak-to-valley average over sampling lengths. They are not interchangeable and there is no universal conversion factor.
• The Rz/Ra ratio typically falls between 4 and 7 on machined surfaces, but it shifts with process, tool wear and material, so converting one from the other is unsafe for acceptance.
• Cut-off length (λc) changes the measured Ra. ISO 4288 ties cut-off to the expected Ra range, and a mismatched cut-off produces readings that look wrong but are technically correct for the wrong filter.
• Turned surfaces are directional. Measure across the feed marks, not along them, or the number is meaningless.
• Write Ra plus measurement direction plus cut-off plus evaluation length on the drawing, or invoke ISO 21920 and let the standard carry the defaults.
What Ra and Rz actually measure
Ra is the arithmetic mean deviation of the roughness profile from its mean line across the evaluation length. Every peak and valley contributes in proportion to its height, so a large number of shallow marks and a small number of deep ones can produce the same Ra.
Rz is the average of the maximum peak-to-valley heights measured in each sampling length. It is sensitive to outliers by design. A surface with a good average but one deep score mark will pass on Ra and fail on Rz.
That difference is why the two numbers are both used in medical work. Implant bearing surfaces and instrument sliding faces care about the general texture because it governs friction and wear. Sealing faces, fluid paths and any surface that will be cleaned and reprocessed care about the deepest valley, because that is where residue sits and where a seal leaks. A single 8 µm deep groove on an otherwise polished face is functionally a defect even if the average looks excellent.
Historical note that matters in practice: ISO 21920 replaced ISO 4287 and ISO 4288 in 2021. Drawings that cite the older standards are still common and still valid as contracts, but you should confirm which parameter definition your supplier's profilometer software is set to. Rz under the older five-point definition and Rz under the current maximum-height definition are not identical, and the difference shows up exactly on the surfaces you care about most.
Why the Rz/Ra ratio is not a fixed number
A rule of thumb says Rz is roughly four to seven times Ra. That range is broad for a reason.
• A sharp, freshly dressed tool cutting a free-machining aluminum produces a fairly regular profile, and its ratio sits near the low end.
• A worn tool, a built-up edge, or chatter pushes the ratio up, because the average barely moves while the deepest valleys get deeper.
• Grinding and lapping produce a different profile family again, often with a lower ratio than turning.
• Ductile materials smear rather than cut cleanly, which changes peak shape without changing average height much.
If a supplier tells you "your Ra 0.4 is about Rz 1.6, so we are fine", the number they quoted may be right for their process and wrong for the surface in front of you. Acceptance should never rest on a converted value. Measure the parameter the drawing actually specifies.
The cut-off length problem
Roughness measurement filters the profile. The cut-off length λc decides what counts as roughness and what is treated as waviness. Change λc and the Ra reading changes on the same physical surface.
ISO 4288 assigns cut-off by expected Ra range. The bands that come up most often in CNC work:
• Expected Ra 0.02 to 0.1 µm uses λc 0.25 mm.
• Expected Ra 0.1 to 2 µm uses λc 0.8 mm.
• Expected Ra 2 to 10 µm uses λc 2.5 mm.
• Expected Ra 10 to 80 µm uses λc 8 mm.
Evaluation length is normally five cut-off lengths. So a Ra 0.4 µm surface measured with λc 0.8 mm is evaluated over 4 mm of traverse. Measure the same surface with λc 2.5 mm and you have folded waviness into the roughness number; the reading will usually rise.
This is the single most common source of "your part failed inspection" arguments on medical work. The part did not change. The filter did. Put λc on the drawing and the argument disappears.
Measurement direction on turned and milled surfaces
Turning produces a helical lay. Roughness measured along the lay is dominated by feed rate and reads far lower than roughness measured across it. ISO and most customer specifications require measurement perpendicular to the lay direction.
On a turned shaft, that means traversing axially across the feed marks, not circumferentially along them. On a face-milled surface, the dominant lay runs in the cutter path direction, so the stylus should cross it.
On five-axis parts with blended tool paths, the lay can change direction across the part. For those, agree with the supplier which regions are critical and how each will be oriented. A single global Ra callout on a part with three different surface orientations is close to unmeasurable in practice.
Why medical drawings need both parameters
Three functional situations push you toward specifying Rz as well as or instead of Ra:
• Sealing faces. An O-ring or gasket seals against the peaks, but a deep valley creates a leak path that no clamp load closes. Rz bounds the valley depth directly.
• Cleanability and reprocessing. Reusable surgical instruments are cleaned, disinfected and sterilized repeatedly. Deep valleys retain biological material and resist cleaning validation. Rz gives you a defensible limit on retained soil.
• Fatigue and crack initiation. Sharp valleys act as stress concentrators. On cyclically loaded implants and instruments, Rz correlates better with fatigue behaviour than Ra.
Conversely, for osseointegration surfaces on dental and orthopedic implants you often want a deliberately rough texture in the Sa 1–2 µm range, produced by blasting or etching rather than machining. That is a different specification with a different intent, and it should be stated separately from any machined surface on the same part. Do not let a blanket "all surfaces Ra 0.8" callout flatten a surface that is supposed to be rough.
How to write the callout
A callout that survives inspection looks like this:
• General surfaces: Ra 3.2 µm, ISO 21920, λc 2.5 mm, measured across lay.
• Sealing faces: Rz ≤ 6.3 µm and Ra ≤ 0.8 µm, λc 0.8 mm, evaluation length 4 mm, measured across lay, 100% of face.
• Sliding or bearing faces: Ra 0.2 µm, λc 0.8 mm, measured across lay, three locations per face.
• Post-process requirement: electropolish per ASTM B912 removing 10–20 µm, then passivate per ASTM A967, achieving Ra ≤ 0.2 µm after processing.
Two habits make a large difference. First, mark critical faces with a symbol or a datum reference rather than relying on prose. Second, state the inspection sampling — one measurement per face, three per face, or 100% — because a single reading on a large face proves very little.
What to do when supplier and customer disagree
Most Ra disputes are procedural, not physical. Work through these in order:
• Confirm both parties used the same parameter definition and standard edition.
• Confirm the same λc and evaluation length.
• Confirm the same measurement direction relative to the lay.
• Confirm the same instrument class and that it was calibrated against a certified specimen on the day of measurement.
• Re-measure the same physical location, marked and photographed, rather than a nearby area.
If the readings still diverge, the surface is genuinely non-uniform and the drawing needs a sampling plan. Do not resolve it by averaging two disagreeing instruments.
Where this fits in a real project
Surface finish is one of three specifications that drive both cost and inspection effort on medical parts, alongside tolerance and material certification. Tightening Ra from 0.8 to 0.4 µm is usually a change of finishing pass and a modest cost increase. Going from 0.4 to 0.1 µm typically moves the part to a different process entirely, and that is where quotes jump.
Finish requirements rarely stand alone. If a drawing on your desk calls for both a clean surface and a Ra target, electropolishing versus passivation explains which of the two processes actually moves the roughness number, and in what order they have to run. Send a drawing and we will come back within 24 working hours with a quote that states which process holds each surface, what inspection method applies, and where a looser callout would save you money without affecting function. One piece is enough to start.